Closed-profile Floor Deck
Closed-profile floor deck has narrow closed ribs and wide flat pans; the ribs are fully wrapped in concrete, so the ends need no closure plugs.

- Profiles we produce
- YXB65-185-555, YXB66-240-720
- How the code reads
- YXB + rib height - rib pitch - cover width, in mm
- Other closed profiles
- Send your drawing; we confirm sizes in the quotation
- Available thickness
- 0.8–1.2 mm
- Minimum thickness in GB/T 12755
- 0.8 mm nominal substrate (floor sheet)
Made on our own lines in Tianjin. Cut to your lengths.
Specifications
| Profiles we produce | YXB65-185-555, YXB66-240-720 |
|---|---|
| How the code reads | YXB + rib height - rib pitch - cover width, in mm |
| Other closed profiles | Send your drawing; we confirm sizes in the quotation |
| Available thickness | 0.8–1.2 mm |
| Minimum thickness in GB/T 12755 | 0.8 mm nominal substrate (floor sheet) |
| Steel grade | S250GD+Z or S350GD+Z |
| Zinc coating | Z180–Z275 |
| Maximum length | Up to 11.8 m for container shipping |
| Ends | Closed ribs: no end closure plugs needed |
| Use | Composite floor slab formwork in steel-frame buildings |
Section drawing
Standards and coatings
For all floor deck: standards and coating options.
Packing and container loading
| Inner protection | Waterproof paper wrap, pallet, steel strapping |
|---|
Bundles of about 3 t: export packing.
Lengths per container: container loading guide.
Order terms
Lead time: 10–20 days after deposit
Minimum order: one 20GP container, products can be mixed.
Payment, Incoterms and inspection: order terms.
Frequently asked questions
What is the difference between open and closed floor deck?
Open deck has wide trapezoidal ribs that are open at the ends. Closed deck has narrow closed ribs and a flatter underside; the ribs are wrapped in concrete, so no end closures are needed. See our open-profile YX models.
What does YXB65-185-555 mean?
A closed profile with 65 mm rib height, 185 mm rib pitch and 555 mm cover width.
Do you publish span tables?
No. We do not publish span or load figures without third-party test reports. Your structural engineer sets the span and propping.
Related products
Sources
- GB/T 12755-2008 listing, chinesestandard.net – values and definitions on this page
Sources checked on 5 November 2026. Typical industry ranges; we confirm the exact values for your order.
Get a Quote for Closed-profile Floor Deck
Send your drawing or size list; we reply with a price.
Working hours: Mon–Sat 8:30–17:30 Beijing time (UTC+8).
Or email sales01@kexinda-industry.com
What a quotation from us includes: see a blank quotation sample.